A2XFY/2XFY, A2XWY/2XWY-3.5 Core Cable

A2XFY/2XFY, A2XWY/2XWY-3.5 Core
A2XFY/2XFY, A2XWY/2XWY-3.5 Core Cross

A2XFY/2XFY, A2XWY/2XWY-3.5 Core Cable

Application

These three-and-a-half-core, armoured cables are designed for power distribution in industrial, commercial, and residential settings, providing a neutral core for three-phase systems, enhanced mechanical protection through galvanised steel strip (A2XFY/2XFY) or wire (A2XWY/2XWY) armouring, and superior thermal performance due to XLPE insulation, suitable for direct burial or exposed installations.

Standard

  • IS 7098 Part 1

Technical Data

  • 1.1 kV (A.C) & 1.5 kV (D.C) to Earth

Cable Construction

  • Conductor: Aluminium or copper stranded compact shaped conductor as per Class 2, IS 8130.
  • Insulation: Crosslinked polyethylene (XLPE).
  • Core Color: Red, yellow, blue.
  • Neutral Core Color: Black.
  • Inner Sheath: PVC or PVC tape as per IS 7098 Part 1.
  • Armouring: Single armouring with galvanised steel strip or wire.
  • Outer Sheath: PVC Type ST-2 as per IS 5831 (Options: FR Type, FRLS Type).
  • Cable Color: Black (Options: Any other color as per requirement).

Cable Design Parameters

While ordering, please specify the following details: Conductor Type (Aluminium or Copper), Class of Conductor (Class 1 or 2), and Sheath Type (PVC Type ST-2, FR, or FRLS).

Part Number Size Cores x mm² + Neutral (mm²) Nominal Thickness of Insulation (mm) (Phase/Neutral) Minimum Thickness of Inner Sheath (mm) Armouring with Flat Strip (A2XFY/2XFY) - Nominal Thickness of Arm. Strip (mm) Armouring with Flat Strip (A2XFY/2XFY) - Minimum Thickness of Outer Sheath (mm) Armouring with Flat Strip (A2XFY/2XFY) - Approx. Overall Diameter (mm) Armouring with Flat Strip (A2XFY/2XFY) - Approx. Net Weight of Cable (kg/km) - Al Cable A2XFY Armouring with Flat Strip (A2XFY/2XFY) - Approx. Net Weight of Cable (kg/km) - Cu Cable 2XFY Armouring with Round Wire (A2XWY/2XWY) - Nominal Diameter of Wire (mm) Armouring with Round Wire (A2XWY/2XWY) - Minimum Thickness of Outer Sheath (mm) Armouring with Round Wire (A2XWY/2XWY) - Approx. Overall Diameter (mm) Armouring with Round Wire (A2XWY/2XWY) - Approx. Net Weight of Cable (kg/km) - Al Cable A2XWY Armouring with Round Wire (A2XWY/2XWY) - Approx. Net Weight of Cable (kg/km) - Cu Cable 2XWY
112101010211 3×25+16 0.9/0.7 0.3 0.8 1.40 23 900 1400 1.6 1.40 25 1080 1685
112101020211 3×35+16 0.9/0.7 0.3 0.8 1.40 25 1000 1800 1.6 1.40 27 1285 1980
112101030211 3×50+25 1.0/0.9 0.3 0.8 1.40 28 1200 2300 1.6 1.56 30 1580 2685
112101040211 3×70+35 1.1/0.9 0.4 0.8 1.56 32 1600 3200 2.0 1.56 35 2190 3690
112101050211 3×95+50 1.1/1.0 0.4 0.8 1.56 35 2000 4100 2.0 1.56 38 2580 4585
112101060211 3×120+70 1.2/1.1 0.4 0.8 1.72 39 2400 5100 2.0 1.72 42 3085 5680
112101070211 3×150+70 1.4/1.1 0.5 0.8 1.72 43 2800 6000 2.0 1.88 46 3590 6790
112101080211 3×185+95 1.6/1.1 0.5 0.8 1.88 47 3400 7400 2.5 2.04 51 4675 8615
112101090211 3×240+120 1.7/1.2 0.6 0.8 2.04 53 4300 9500 2.5 2.20 56 5680 10485
112101100211 3×300+150 1.8/1.4 0.6 0.8 2.20 57 5000 11500 2.5 2.36 60 6685 12990
112101110211 3×400+185 2.0/1.6 0.7 0.8 2.52 66 6400 14500 3.2 2.68 71 8980 16980
112101120211 3×500+240 2.2/1.7 0.7 0.8 2.68 74 7900 18000 3.2 2.84 79 10985 21485
112101130211 3×630+300 2.4/1.8 0.7 0.8 3.00 82 9900 23000 4.0 3.00 88 14490 27985
  • For conductor and resistance, refer to table no. 16-1.
  • For capacitance, reactance, and short circuit rating, refer to tables no. 16-5, 16-6, and 16-7.
  • For current rating, refer to table no. 16-4.

Electrical Parameters

Electrical parameters such as conductor resistance, capacitance, reactance, short circuit rating, and current rating are available in referenced tables (16-1, 16-4, 16-5, 16-6, 16-7). Please contact us for detailed specifications.