A2XY/2XY-1 Core Cable

A2XY/2XY-1 Core
A2XY/2XY-1 Core Cross

A2XY/2XY-1 Core Cable

Application

These single-core, unarmoured cables are designed for power transmission and distribution in industrial, commercial, and residential settings, offering high electrical conductivity with aluminium (A2XY) or copper (2XY) conductors and superior thermal performance due to XLPE insulation, suitable for direct burial or exposed installations.

Standard

  • IS 7098 Part 1

Technical Data

  • 1.1 kV (A.C) & 1.5 kV (D.C) to Earth

Cable Construction

  • Conductor: Aluminium (up to 10 mm² solid Class 1, above 10 mm² stranded round or compact Class 2) or Copper (4 & 6 mm² solid Class 1 or stranded Class 2, 10 mm² and above stranded round or compact Class 2) as per IS 8130.
  • Insulation: Crosslinked polyethylene (XLPE).
  • Core Color: Red, yellow, blue, black, or natural.
  • Outer Sheath: PVC Type ST-2 as per IS 5831 (Options: FR Type, FRLS Type).
  • Cable Color: Black (Options: Any other color as per requirement).

Cable Design Parameters

While ordering, please specify the following details: Conductor Type (Aluminium or Copper), Class of Conductor (Class 1 or 2), Sheath Type (PVC Type ST-2, FR, or FRLS), and Core Color.

Part Number Nominal Cross Sectional Area (mm²) Nominal Thickness of Insulation (mm) Nominal Thickness of Outer Sheath (mm) Approx. Overall Diameter (mm) Approx. Net Weight of Cable (kg/km) - Al Cable A2XY Approx. Net Weight of Cable (kg/km) - Cu Cable 2XY
111300100016 16 0.7 1.8 11 125 225
111300100025 25 0.9 1.8 12 170 330
111300100035 35 0.9 1.8 13 205 425
111300100050 50 1.0 1.8 15 250 550
111300100070 70 1.1 1.8 16 335 750
111300100095 95 1.1 1.8 18 425 1000
111300100120 120 1.2 1.8 20 515 1250
111300100150 150 1.4 2.0 22 615 1520
111300100185 185 1.6 2.0 24 770 1880
111300100240 240 1.7 2.0 27 965 2415
111300100300 300 1.8 2.0 30 1160 2980
111300100400 400 2.0 2.2 33 1480 3800
111300100500 500 2.2 2.2 36 1840 4815
111300100630 630 2.4 2.2 40 2350 6150
111300100800 800 2.6 2.4 47 2830 7840
111300101000 1000 2.8 2.6 51 3670 9800
  • For conductor and resistance, refer to table no. 16-1.
  • For capacitance, reactance, and short circuit rating, refer to tables no. 16-5, 16-6, and 16-7.
  • For current rating, refer to table no. 16-2.

Electrical Parameters

Electrical parameters such as conductor resistance, capacitance, reactance, short circuit rating, and current rating are available in referenced tables (16-1, 16-2, 16-5, 16-6, 16-7). Please contact us for detailed specifications.